{"product_id":"merck-flat-bag-assembly","title":"Merck Flat Bag Assembly","description":"\u003cp class=\"MuiTypography-root jss135 MuiTypography-h1\" data-testid=\"npae-product-name\"\u003e\u003cstrong\u003e\u003cspan id=\"product-name\"\u003eNovaSeptum\u003csup\u003e®\u003c\/sup\u003e High Purity Unit, Flat Bag Assembly, 100 mL, sterile\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"0\" data-end=\"241\"\u003eNovaSeptum® High Purity Unit provides secure, aseptic sampling for critical applications. Its closed design minimizes contamination risk and helps maintain sample integrity from collection through analysis.\u003c\/p\u003e\n\u003cp data-start=\"243\" data-end=\"261\"\u003e\u003cstrong data-start=\"243\" data-end=\"259\"\u003eKey Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"262\" data-end=\"617\"\u003e\n\u003cli data-start=\"262\" data-end=\"352\"\u003e\n\u003cstrong data-start=\"264\" data-end=\"281\"\u003eClosed System\u003c\/strong\u003e: Prevents external contamination and reduces false-positive results.\u003c\/li\u003e\n\u003cli data-start=\"353\" data-end=\"426\"\u003e\n\u003cstrong data-start=\"355\" data-end=\"373\"\u003eCompact Design\u003c\/strong\u003e: No dead leg, helping conserve valuable materials.\u003c\/li\u003e\n\u003cli data-start=\"427\" data-end=\"523\"\u003e\n\u003cstrong data-start=\"429\" data-end=\"455\"\u003eVersatile Connectivity\u003c\/strong\u003e: Standard and custom connectors adapt to various sampling points.\u003c\/li\u003e\n\u003cli data-start=\"524\" data-end=\"617\"\u003e\n\u003cstrong data-start=\"526\" data-end=\"541\"\u003eLow Binding\u003c\/strong\u003e: Ideal for proteins, complex carbohydrates, or small-molecule applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"619\" data-end=\"637\"\u003e\u003cstrong data-start=\"619\" data-end=\"635\"\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"638\" data-end=\"777\"\u003e\n\u003cli data-start=\"638\" data-end=\"675\"\u003eBacterial counting in bioreactors\u003c\/li\u003e\n\u003cli data-start=\"676\" data-end=\"718\"\u003eAseptic and sterile sampling processes\u003c\/li\u003e\n\u003cli data-start=\"719\" data-end=\"777\"\u003eSituations requiring minimal sample loss and high-purity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"779\" data-end=\"811\"\u003e\u003cstrong data-start=\"779\" data-end=\"809\"\u003eMaterials and Construction\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"812\" data-end=\"997\"\u003e\n\u003cli data-start=\"812\" data-end=\"851\"\u003e316L stainless steel cannula (ASTM)\u003c\/li\u003e\n\u003cli data-start=\"852\" data-end=\"917\"\u003eMedical-grade TPE tubing and silicone septum (platinum-cured)\u003c\/li\u003e\n\u003cli data-start=\"918\" data-end=\"936\"\u003ePolyester body\u003c\/li\u003e\n\u003cli data-start=\"937\" data-end=\"997\"\u003eTwo polyethylene bags (one for drainage, one for sampling)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"999\" data-end=\"1026\"\u003e\u003cstrong data-start=\"999\" data-end=\"1024\"\u003eSterility and Quality\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1027\" data-end=\"1183\"\u003e\n\u003cli data-start=\"1027\" data-end=\"1092\"\u003eBeta irradiated at a minimum of 25 kGy (ISO 11137 TIR No. 27)\u003c\/li\u003e\n\u003cli data-start=\"1093\" data-end=\"1141\"\u003eQuality Level 400 for consistent performance\u003c\/li\u003e\n\u003cli data-start=\"1142\" data-end=\"1183\"\u003eEndotoxin levels ≤2.15 EU\/mL (LAL test)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1185\" data-end=\"1215\"\u003e\u003cstrong data-start=\"1185\" data-end=\"1213\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1216\" data-end=\"1504\"\u003e\n\u003cli data-start=\"1216\" data-end=\"1280\"\u003e\n\u003cstrong data-start=\"1218\" data-end=\"1243\"\u003eOperating Temperature\u003c\/strong\u003e: -20 °C to 50 °C (-4 °F to 122 °F)\u003c\/li\u003e\n\u003cli data-start=\"1281\" data-end=\"1330\"\u003e\n\u003cstrong data-start=\"1283\" data-end=\"1308\"\u003eMax Sampling Pressure\u003c\/strong\u003e: 0.3 bar (4.35 psi)\u003c\/li\u003e\n\u003cli data-start=\"1331\" data-end=\"1358\"\u003e\n\u003cstrong data-start=\"1333\" data-end=\"1348\"\u003eNeedle Size\u003c\/strong\u003e: 2.0 mm\u003c\/li\u003e\n\u003cli data-start=\"1359\" data-end=\"1419\"\u003e\n\u003cstrong data-start=\"1361\" data-end=\"1374\"\u003ePackaging\u003c\/strong\u003e: Pack of 5 × 50 mL (for a total of 100 mL)\u003c\/li\u003e\n\u003cli data-start=\"1420\" data-end=\"1463\"\u003e\n\u003cstrong data-start=\"1422\" data-end=\"1431\"\u003eInlet\u003c\/strong\u003e: Septum unit with 2 mm needle\u003c\/li\u003e\n\u003cli data-start=\"1464\" data-end=\"1504\"\u003e\n\u003cstrong data-start=\"1466\" data-end=\"1476\"\u003eOutlet\u003c\/strong\u003e: Three-piece Luer fitting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MuiTypography-root jss135 MuiTypography-h1\" data-testid=\"npae-product-name\"\u003eVolume: 100 mL \u003c\/p\u003e\n\u003cp class=\"MuiTypography-root jss135 MuiTypography-h1\" data-testid=\"npae-product-name\"\u003eExpiration Date: \u003cspan data-sheets-root=\"1\"\u003e30\/04\/2025\u003c\/span\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--td {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}--\u003e\u003c\/style\u003e\n\u003cp class=\"MuiTypography-root jss135 MuiTypography-h1\" data-testid=\"npae-product-name\"\u003eCatalog Number: \u003cspan\u003e2714-10100\u003c\/span\u003e\u003c\/p\u003e","brand":"Merck","offers":[{"title":"Sterile \/ 100 mL \/ Case of 5 \/ New - Open Box (Items Sealed) \/ 30-04-2025","offer_id":51272420852039,"sku":"2714-10100","price":1223.23,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/7245\/8055\/files\/Screenshot_19-3-2025_10824_www.sigmaaldrich.com.jpg?v=1742368172","url":"https:\/\/checkout.wasteless.bio\/products\/merck-flat-bag-assembly","provider":"Wasteless Bio","version":"1.0","type":"link"}